NxModbus is a lightweight Modbus protocol stack implementation for NuttX RTOS. This commit adds: - nxmodbus stack - nxmbserver - Modbus Server (Slave) example - nxmbclient - Modbus Client (Master) tool Supported Modbus transports: - ASCII - RTU over serial port - TCP - RAW (ADU) for custom transport implementations Signed-off-by: raiden00pl <raiden00@railab.me>
245 lines
6.9 KiB
Text
245 lines
6.9 KiB
Text
#
|
|
# For a description of the syntax of this configuration file,
|
|
# see the file kconfig-language.txt in the NuttX tools repository.
|
|
#
|
|
|
|
menuconfig INDUSTRY_NXMODBUS
|
|
bool "NxModbus - New Modbus Stack"
|
|
default n
|
|
---help---
|
|
NxModbus is a modern Modbus stack for NuttX with multi-instance
|
|
support, per-instance register callbacks, and pluggable transport
|
|
backends (RTU, ASCII, TCP, Raw ADU).
|
|
|
|
This implementation follows NuttX coding standards and is
|
|
designed for upstream contribution to nuttx-apps.
|
|
|
|
if INDUSTRY_NXMODBUS
|
|
|
|
config NXMODBUS_SERVER
|
|
bool "Server (slave) support"
|
|
default y
|
|
---help---
|
|
Enable Modbus server (slave) support. The server processes
|
|
incoming Modbus requests and calls registered register
|
|
callbacks.
|
|
|
|
config NXMODBUS_CLIENT
|
|
bool "Client (master) support"
|
|
default n
|
|
---help---
|
|
Enable Modbus client (master) support. The client sends
|
|
Modbus requests to a server and receives responses.
|
|
|
|
config NXMODBUS_RTU
|
|
bool "Modbus RTU mode"
|
|
default y
|
|
---help---
|
|
Enable Modbus RTU (Remote Terminal Unit) serial transmission
|
|
mode. Uses binary encoding with CRC16 error checking.
|
|
|
|
config NXMODBUS_ASCII
|
|
bool "Modbus ASCII mode"
|
|
default n
|
|
---help---
|
|
Enable Modbus ASCII serial transmission mode. Uses
|
|
hex-encoded text with LRC error checking. Slower but
|
|
more human-readable than RTU.
|
|
|
|
config NXMODBUS_TCP
|
|
bool "Modbus TCP mode"
|
|
default n
|
|
depends on NET_TCP
|
|
---help---
|
|
Enable Modbus TCP support. Modbus frames are encapsulated
|
|
in TCP/IP using the MBAP header format. Requires network
|
|
stack with TCP support.
|
|
|
|
config NXMODBUS_RAW_ADU
|
|
bool "Raw ADU transport support"
|
|
default n
|
|
---help---
|
|
Enable raw ADU (Application Data Unit) transport mode.
|
|
The application provides callbacks for transmitting and
|
|
receiving raw Modbus frames. This enables custom transports
|
|
such as TLS, CAN, BLE, or MQTT.
|
|
|
|
config NXMODBUS_MAX_INSTANCES
|
|
int "Maximum number of NxModbus instances"
|
|
default 1
|
|
range 1 16
|
|
---help---
|
|
Maximum number of simultaneous NxModbus instances. Each
|
|
instance can use a different transport (RTU, TCP, etc.)
|
|
and configuration. Instances are allocated from a static
|
|
pool at compile time.
|
|
|
|
config NXMODBUS_ADU_DATA_MAX
|
|
int "ADU data buffer size in bytes"
|
|
default 252
|
|
range 4 252
|
|
---help---
|
|
Size of the data[] payload in struct nxmb_adu_s, in bytes.
|
|
This is the PDU body after the function code. The Modbus
|
|
specification allows up to 252 data bytes (1 fc + 252 data =
|
|
253-byte PDU max). Reduce this value to save RAM on
|
|
resource-constrained systems.
|
|
|
|
config NXMODBUS_REP_SERVER_ID_BUF
|
|
int "Report Server ID buffer size"
|
|
default 32
|
|
range 4 253
|
|
---help---
|
|
Size of the buffer used by FC17 (Report Server ID).
|
|
This buffer holds the server ID byte, run indicator, and
|
|
optional additional data configured via nxmb_set_server_id().
|
|
|
|
config NXMODBUS_ASCII_TIMEOUT_SEC
|
|
int "ASCII character timeout (seconds)"
|
|
default 1
|
|
range 1 60
|
|
depends on NXMODBUS_ASCII
|
|
---help---
|
|
Character timeout for Modbus ASCII mode in seconds. If no
|
|
character is received within this period, the current frame
|
|
is discarded. Default is 1 second per the Modbus specification.
|
|
|
|
config NXMODBUS_CLIENT_TIMEOUT_MS
|
|
int "Client default response timeout (ms)"
|
|
default 1000
|
|
range 100 60000
|
|
depends on NXMODBUS_CLIENT
|
|
---help---
|
|
Default response timeout for client (master) mode in
|
|
milliseconds. If no response is received from the server
|
|
within this period, the request fails with ETIMEDOUT.
|
|
Can be overridden at runtime via nxmb_set_timeout().
|
|
|
|
config NXMODBUS_TCP_MAX_CLIENTS
|
|
int "Maximum simultaneous TCP client connections"
|
|
default 1
|
|
range 1 8
|
|
depends on NXMODBUS_TCP
|
|
---help---
|
|
Maximum number of simultaneous TCP client connections
|
|
accepted by a Modbus TCP server instance. Each connection
|
|
uses one file descriptor. Set to 1 for minimal resource
|
|
usage.
|
|
|
|
config NXMODBUS_TCP_TIMEOUT_SEC
|
|
int "TCP idle connection timeout (seconds)"
|
|
default 60
|
|
range 1 3600
|
|
depends on NXMODBUS_TCP
|
|
---help---
|
|
Idle timeout for TCP connections in seconds. If no data is
|
|
received on a client connection within this period, the
|
|
connection is closed. Set to a higher value for slow networks.
|
|
|
|
config NXMODBUS_RTU_IDLE_TIMEOUT_MS
|
|
int "RTU inter-frame idle timeout (ms)"
|
|
default 50
|
|
range 1 1000
|
|
depends on NXMODBUS_RTU
|
|
---help---
|
|
Fallback idle timeout in milliseconds used by the RTU
|
|
transport when waiting for a new frame via select(). This
|
|
is the maximum time to block waiting for data when no
|
|
frame is in progress. The T3.5 character timing is still
|
|
used for frame delimiting within an active reception.
|
|
|
|
menu "Function Code Selection"
|
|
|
|
config NXMODBUS_FUNC_READ_COILS
|
|
bool "FC01 Read Coils"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC01 Read Coils function code handler.
|
|
|
|
config NXMODBUS_FUNC_READ_DISCRETE
|
|
bool "FC02 Read Discrete Inputs"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC02 Read Discrete Inputs function code handler.
|
|
|
|
config NXMODBUS_FUNC_READ_HOLDING
|
|
bool "FC03 Read Holding Registers"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC03 Read Holding Registers function code handler.
|
|
|
|
config NXMODBUS_FUNC_READ_INPUT
|
|
bool "FC04 Read Input Registers"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC04 Read Input Registers function code handler.
|
|
|
|
config NXMODBUS_FUNC_WRITE_COIL
|
|
bool "FC05 Write Single Coil"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC05 Write Single Coil function code handler.
|
|
|
|
config NXMODBUS_FUNC_WRITE_HOLDING
|
|
bool "FC06 Write Single Holding Register"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC06 Write Single Holding Register function
|
|
code handler.
|
|
|
|
config NXMODBUS_FUNC_DIAGNOSTICS
|
|
bool "FC08 Diagnostics"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC08 Diagnostics function code handler.
|
|
Only sub-function 0x0000 (Return Query Data) is supported.
|
|
|
|
config NXMODBUS_FUNC_WRITE_COILS
|
|
bool "FC15 Write Multiple Coils"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC15 Write Multiple Coils function code handler.
|
|
|
|
config NXMODBUS_FUNC_WRITE_HOLDINGS
|
|
bool "FC16 Write Multiple Holding Registers"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC16 Write Multiple Holding Registers function
|
|
code handler.
|
|
|
|
config NXMODBUS_FUNC_REPORT_SERVER_ID
|
|
bool "FC17 Report Server ID"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC17 Report Server ID function code handler.
|
|
|
|
config NXMODBUS_FUNC_READWRITE_HOLDINGS
|
|
bool "FC23 Read/Write Multiple Holding Registers"
|
|
default y
|
|
depends on NXMODBUS_SERVER
|
|
---help---
|
|
Enable FC23 Read/Write Multiple Holding Registers
|
|
function code handler.
|
|
|
|
endmenu # Function Code Selection
|
|
|
|
config NXMODBUS_CUSTOM_FC
|
|
bool "Custom function code extension support"
|
|
default y
|
|
depends on NXMODBUS
|
|
---help---
|
|
Enable support for registering custom Modbus function
|
|
code handlers. Applications can extend the Modbus
|
|
function code set via nxmb_register_custom_fc().
|
|
|
|
endif # INDUSTRY_NXMODBUS
|